Diazyme Enzymatic Lithium Two Level Control Set

https://www.myco-instrumentation.com/web/image/product.template/84493/image_1920?unique=f73ae0f

Diazyme Enzymatic Lithium Two Level Control Set
MUST SHIP OVERNIGHT

In Stock

139.64 139.64000000000001 USD 139.64

139.64

This combination does not exist.

Get your quote in 90 minutes.
Trade in your older analyzers to recover budget.
Bundle equipment, reagents, & consumables into one cost-saving order.
Enlist our local service tech to keep uptime high.
Lower your cost per test.

Product Code: DZ116B-CON

Manufacturer: Diazyme

Shipping Weight: 5.00lbs (2.27kg)

WHY CHOOSE MYCO INSTRUMENTATION?
See Why in 2 mins.

Diazyme Enzymatic Lithium Two Level Control Set

Enzymatic Lithium Two (2) Level Control Set (lyophilized), Con: 2 x 3 mL vials

Diazyme's Lithium Assay provides a convenient, stable, non-caustic low cost alternative to expensive ISE and highly caustic alkaline Lithium methods. Diazyme's Lithium Assay demonstrates an excellent correlation with ISE methods and offers excellent precision CV% of <5% and a measuring range from 0.19 mmol/L – 3.0 mmol/L. The assay is not interfered by the following substances at indicated concentrations: Na+ 200 mM, NH4+ 0.5 mM, Ca2+ 4.0 mM, Mg2+ 2.0 mM, ascorbic acid 5.0 mM, 0.25 mM Zn2+, 0.25 mM Fe3+, 0.25 mM Cu2+, 10 mM K+, Triglycerides 1000 mg/dL, conjugated bilirubin 20 mg/dL and unconjugated bilirubin 45 mg/ dL, Ascorbic Acid 5 mM and hemoglobin 500 mg/dL.


Assay Principle

Lithium is determined spectrophotometrically through a kinetic coupled enzyme assay system involving Diazyme's proprietary phosphatase1 whose activity is sensitive to lithium (IC50=0.1mM). Through enzymatic coupling, the phosphatase substrate is converted to hypoxanthine by a series of enzymatic reactions to generate uric acid and hydrogen peroxide (H2O2). H2O2 generated reacts with N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4-AA) in the presence of peroxidase (POD) to form a quinone dye which has maximal absorbance at 556 nm. The rate of the quinine dye formation is inversely proportional to the concentration of lithium in serum samples.


Intended use

Diazyme Lithium Enzymatic Assay kit is for quantitative in vitro determination of lithium in human serum. Measurements of Lithium are carried out essentially to ensure that proper drug dosage is administered in the treatment of patient suffering from bipolar disorder and to avoid toxicity.