ABX Pentra 400

https://www.myco-instrumentation.com/web/image/product.template/82991/image_1920?unique=6057e9d

The ABX Pentra 400 is a compact Clinical Chemistry benchtop analyzer with continuous loading, offering user-friendly lab productivity. FDA cleared, it can handle up to 55 assays.

In Stock

0.00 0.0 USD 0.00

0.00

This combination does not exist.

Get your quote in 90 minutes.
Trade in your older analyzers to recover budget.
Bundle equipment, reagents, & consumables into one cost-saving order.
Enlist our local service tech to keep uptime high.
Lower your cost per test.

Product Code: ABXP400

WHY CHOOSE MYCO INSTRUMENTATION?
See Why in 2 mins.

ABX Pentra 400 

This system is a compact Clinical Chemistry benchtop analyzer. It boasts of productivity with continuous loading and provides a user friendly instrument for any lab.

  • Analysis Method Types:
    • Spectrophotometry: Colorimetry and Turbidimetry
    • Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
  • Up to 55 assays on board
  • Optional ISE Module (Na+, K+, Cl-)
  • Maximum Throughput: 420 test/h
  • FDA cleared


Sample Handling

  • Sample Capacity: 6 racks with 10 sample positions for primary tubes or cups
  • Continuous loading
  • Positive Sample Identification: Int.ted Barcode Reader and Tube Presence Detector
  • Sample Integrity:Level, Shock and Clot Detection
  • Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: 16mm)
  • Sample Specimen: Serum, Plasma, Urine, CSF, Whole Blood, Homogeneous Fluids
  • Sample Volume: 2 to 380 µL
  • Automatic Sample Dilution: from 1/2 to 1/22,500
  • ISE: 10 µL (Indirect) or 65 µL (Direct)
  • Automatic Post Concentration: from x2.0 to x 10.0
  • Automatic Re-run


Calibrator/Control Handling

  • Calibrator/Controls Positioning on Sample or Reagent Tray
  • Automatic Standard Dilution Series:
    • Dilution Factors: Main Direct 1/2 – 1/150
    • Dilution Factors: Main Indirect 1/2 – 1/1508


Reagent Handling

  • 52 Reagent positions on board:
    • 44 in a closed refrigerated area (2-10°C)
    • 8 at room temperature
  • Positive Reagent Identification:Int.ted Barcode Reader
  • Reagent Probe: Level Detection and Preheating
  • Reagent Management with Cassettes: Automated Reagent On-board Stability Check plus Test Countdown with automatic back-up
  • Reagent Volume: from 2 to 600 µL


Reaction System

  • Reaction Volume: 150 to 600 µL
  • Reaction Temperature: Air bath at 37°C
  • Photometer Reaction Cycle:12 seconds
  • Mixing with Teflon-coated Stirrer
  • Reaction Time:  1 to 100 cycles
  • Disposable Acrylic Cuvettes
  • Automatic Cuvette Changer
  • Cuvette Capacity:  36 segments (432 cuvettes)
  • 7 Int.ted Calculation Algorithms


  • Weight: 264 Lbs;  External Cooling Unit: 77 Lbs
  • Dimensions: 40” x 28” x 25” (W x L x H)
  • External Cooling Unit: 12” x 17” x 16” (W x L x H)